All Sea Recovery Watermakers - General Specifications
Product Water Production Stated Per Hour and Per Day of Operation
Based in +- 15% at 800 psi / 55 Bar, 77°F/25°C, 35,000 PPM TDS
Salt Rejection (Chloride Ion)
99.4%
Product Water Temperature
Ambient to feed water temperature
Salinity Monitoring
Automatic computer controlled electronic monitoring with continuous readout in micromhos per cubic centimeter, are temperature compensation and of a state of a fail-safe design.
Salinity Range of Feed Water
Seawater up to 50,000 PPM TDS (NaCI) (typically seawater salinity is 35,000 PPM TDS NaCI)
Temperature Range
Max 122°F / 50°C Min. 33°F / .5°C
Reverse Osmosis Membrane
Specifically selected high rejection / high yield aromatic tri-polyamid, thin film composite, spiral wound, single pass reverse osmosis membrane element.
Chlorine Tolerance
1000 hours @ 0.1 PPM, pH range 3-11
Feed Water Pressure
Min 6 PSI / .42 Kg/cm2 / 41.4 kPa.
Max 40 PSI / 2.8 Kg/cm2 / 275.8 kPa.
Operating Pressure
From seawater @ 35,000 PPM & 77°F
Nominal 800 pSI / 56.25 Kg/cm2 / 5516 kPa
|